LIVE
UTC --:--:--
OT SECURITY HUB
by zuckergates
// MODULE · FRAMEWORKS

OT / ICS frameworks & standards

30 kerangka kerja & standar — telusuri, bandingkan, dan lacak status adopsi di program OT security Anda.

Total framework
30
Wajib (regulasi)
10
Sedang diimplementasi
0
Sudah diadopsi
0
Status adopsi:Belum dinilaiEksplorasiImplementasiDiadopsi
US EPAUSWajib2018

America Water Infrastructure Act (AWIA)

Water Utility

Wajib risk & resilience assessment serta emergency response plan.

Biaya $Effort SedangRRAERP
↗ sumber
AWWAUS2019

AWWA Cybersecurity Guidance

Water Utility

Panduan praktis untuk water utility USA sesuai AWIA.

Biaya $Effort RendahRiskAWIA alignment
↗ sumber
CISAUS2023

CISA Cross-Sector CPGs

Critical Infrastructure Baseline

Baseline minimal untuk critical infrastructure US.

Biaya $Effort RendahAccount securityDeviceNetworkSupply chain+1
↗ sumber
CENELECEU2021

CLC/TS 50701

Railway Cybersecurity

Cyber framework untuk rolling stock dan sinyalisasi rel EU.

Biaya $$Effort TinggiRolling stockSignaling
↗ sumber
US DoDUSWajib2015

DoDI 8530

DoD Industrial Control

Direktif keamanan ICS untuk fasilitas militer USA.

Biaya $$$Effort TinggiCSSPAuthorization
↗ sumber
US DOEGlobal2022

DOE C2M2

Cyber Capability Maturity Model

Self-assessment maturity model untuk operator energi.

Biaya $Effort Rendah10 domain maturity
↗ sumber
EUEUWajib2024

EU Cyber Resilience Act (CRA)

Connected Products

Persyaratan keamanan siklus hidup produk dengan elemen digital di EU.

Biaya $$Effort TinggiSBOMVuln handlingCE marking
↗ sumber
IECGlobalWajib2016

IEC 61511

Functional Safety Process Industries

Standar safety untuk SIS di industri proses; komplemen 62443 dari sisi safety.

Biaya $$Effort TinggiSIS lifecycleSILCyber pada SIS
↗ sumber
IECGlobal2007

IEC 62351

Power System Communication Security

Keamanan komunikasi power system (IEC 61850, 60870).

Biaya $$Effort SedangCrypto IEC 61850/60870Auth GOOSE/SV
↗ sumber
IECGlobal2015

IEC 62443-2-4

Service Provider Requirements

Persyaratan keamanan bagi system integrator dan service provider IACS.

Biaya $$Effort SedangService provider
IECGlobal2020

IEC 62443-3-2

Risk Assessment

Metodologi zone & conduit dan SL-T per zona.

Biaya $$Effort SedangZCR 1-7SL-T
IECGlobal2019

IEC 62443-4-2

Component Security Requirements

Persyaratan teknis untuk perangkat IACS individu (CR & RE).

Biaya $$Effort TinggiCR 1-7RE per SL
ISAGlobal2017

ISA TR84.00.09

Cyber Security in SIS

Panduan integrasi cybersecurity ke Safety Instrumented System.

Biaya $$Effort TinggiCyber dalam SIS lifecycle
↗ sumber
ISAGlobal2021

ISA TR84.00.09 (v2)

Cyber + Safety integration

Panduan integrasi cybersecurity ke SIS dengan klausul ASD.

Biaya $$Effort TinggiASD klausul
ISA + IECGlobal2018

ISA/IEC 62443

Industrial Automation & Control Systems

Seri standar paling komprehensif untuk keamanan IACS · wajib bagi praktisi OT.

Biaya $$Effort TinggiGovernanceRiskZone & ConduitKomponen+1
↗ sumber
ISO/IECGlobal2017

ISO/IEC 27019

Energy Utility Industry

Ekstensi ISO 27002 untuk industri energi listrik dan gas.

Biaya $$Effort SedangExtension ISO 27002 untuk energi
↗ sumber
Kementerian ESDM RI

Kepmen ESDM 184.K/2025

Cybersecurity Sektor Migas

Pedoman keamanan siber sektor minyak & gas Indonesia dengan rujukan eksplisit ke IEC 62443.

MITREGlobal2020

MITRE ATT&CK for ICS

Threat Behavior Knowledge Base

Knowledge base TTP adversary di lingkungan ICS.

Biaya $Effort SedangTTPTactics 12Mitigations
↗ sumber
NERCUSWajib2008

NERC CIP

Bulk Electric System North America

Standar wajib untuk operator grid listrik di Amerika Utara.

Biaya $$$Effort TinggiAsset categorizationPersonnelElectronic perimeterPhysical+1
↗ sumber
EUEUWajib2023

NIS2 Directive

EU Cybersecurity Regulation

Mewajibkan risk management, reporting, dan supply chain security.

Biaya $$Effort TinggiRisk mgmtIncident reportingSupply chainGovernance liability
↗ sumber
NISTGlobal2024

NIST CSF 2.0

Enterprise Cybersecurity

Framework manajemen risiko universal; CSF 2.0 menambahkan fungsi Govern.

Biaya $Effort RendahGovernIdentifyProtectDetect+2
↗ sumber
NISTUS2023

NIST SP 800-82 Rev 3

OT Security

Panduan resmi US untuk mengamankan OT termasuk ICS, SCADA, DCS, dan PLC.

Biaya $Effort SedangArsitekturRiskKontrol teknisIR+1
↗ sumber
BSSN

Pedoman OT Security BSSN

OT/ICS Indonesia

Pedoman teknis BSSN untuk pengamanan OT/ICS pada penyelenggara sistem elektronik & infrastruktur vital nasional.

Pemerintah RI

Perpres 82/2022 (IIV)

Infrastruktur Informasi Vital

Mengatur pelindungan Infrastruktur Informasi Vital (IIV) lintas sektor strategis termasuk energi — landasan kewajiban OT security operator vital.

PurdueGlobal1990

Purdue Reference Model

Network Segmentation Industrial

Model layering 6-level yang menjadi dasar segmentasi jaringan OT modern.

Biaya $Effort SedangLevel 0–5IDMZZona logis
↗ sumber
US SECUSWajib2023

SEC Cyber Disclosure

Public Companies

Aturan 4-hari pelaporan insiden cyber material termasuk OT.

Biaya $Effort SedangMaterial incident disclosure
↗ sumber
US SECUSWajib2023

SEC Cybersecurity Disclosure Rule

Public Companies

Aturan 8-K 4 hari pelaporan insiden cyber material.

Biaya $Effort Sedang8-K Item 1.05
↗ sumber
ENX (German Auto)EUWajib2017

TISAX

Automotive Supply Chain

Standar info-sec & prototype protection wajib supplier otomotif Jerman.

Biaya $$$Effort TinggiInfo-secPrototype protection
↗ sumber
TSAUSWajib2021

TSA Pipeline Security Directive

US Pipeline Operators

Direktif pasca Colonial Pipeline · mandatory 24h reporting.

Biaya $$Effort TinggiReporting 24hArchitecture reviewIR plan
↗ sumber
Pemerintah RI

UU PDP No. 27/2022

Pelindungan Data Pribadi Indonesia

Undang-undang Pelindungan Data Pribadi Indonesia · kewajiban pengamanan data & notifikasi pelanggaran (denda hingga 2% pendapatan).